| | AC(交流)瓦特(50或60Hz,PF(功率因素)0.5到1.CT(比流器比值)=1)  | 
  | 范围  | 分辨率  | 读值准确度 (6800+6801)  | 读值准确度 (6800+6802)  | 读值准确度 (6800+3007)  |  | 5.0 – 99.9W  | 0.1W  | ±1% ± 0.8 w  | ±1% ± 0.8 w  | ±1% of Range  |  | 1.000 – 9.999 KW  | 0.001 KW  | ±1% ± 8 w  | ±1% ± 8 w  | ±1% of Range  |  | 10.00 – 99.99 KW  | 0.01 KW  | ±1% ± 8 0w  | ±1% ± 8 0w  | ±1% of Range  |  | 100.0 – 999.9 KW  | 0.1 KW  | ±1% ± 0.8kw  | ±1% ± 0.8kw  | ±1% of Range  |  | 1000 – 9999 KW  | 1 KW  | ±1% ± 8kw  | ±1% ± 8kw  | ±1% of Range  |  | 0.000 – 9.999MW  | 0.001MW  | –  | ±1% ± 8 0kw  | –  | 
 | 
| | AC(交流)电流( 50 或 60Hz,自动檔位,真均方根值,波峰因素<4< span="">,CT=1) 4<> | 
  |   | 范围  | 分辨率  | 读值准确度  |  | 6800+6801  (超载保护 AC200A)  | 0.050 – 9.999A  | 0.00A  | ±0.5% ± 0.05A  |  | 10.00 – 60.00A  | 0.01A  | ±0.5% ± 0.5A  |  | 60.00 – 99.99A  | 0.01A  | ±0.1% ± 0.5A  |  | 6800+6802  (超载保护 AC2000A)  | 0.04 – 10.00A  | 0.01A  | –  |  | 0.4A – 100.0A  | 0.1A  | ±0.5% ± 0.5A  |  | 4.0 – 1000.0A  | 1A  | ±0.5% ± 5A  |  | 6800+ 3007  (超载保护 AC3500A)  | 4 – 300A  | 0.1A  | ±1% of Range  |  | 300.0 – 999.9A  | 0.1A  | ±1% of Range  |  | 1000 – 3000A  | 1A  | ±1% of Range  | 
 | 
| | AC(交流)电压 ( 50 或 60 Hz,自动檔位,真均方根值,波峰因素<4< span="">,输入阻抗10M Ω ,VT(PT)=1CT=1,800V超载保护) 4<> | 
  | 范围  | 分辨率  | 读值准确度  | 范围  | 分辨率  | 读值准确度  |  | 4.0V – 500.0 (Phase to Neutral)  | 0.1V  | ± 0.5% ± 5dgts  | 4.0V – 600.0V (Phase to phase)  | 0.1V  | ± 0.5% ± 5dgts  | 
 | 
| | AC(交流)电流的谐波分析(1~99阶)6802大电流钩部  | 
  | 范围  | 百分比(%)  | 电流值(A)  |  | 分辨率  | 读值准确度  | 分辨率  | 读值准确度  |  | 1 – 20 th  | 0.1%  | ±2%  | 0.1 A  | ±2% of reading ± 0.4A  |  | 21 – 50 th  | 4% of reading ±2.0%  | ±4% of reading ±0.4A  |  | 51 – 99 th  | 6% of reading ±2.0%  | ±6% of reading ±0.4A  | 
 | 
| | AC(交流)电流的谐波强度(1~99阶)6801小电流钩部,适合CT  | 
  | 范围  | 百分比(%)  | 电流值(A)  |  | 分辨率  | 读值准确度  | 分辨率  | 读值准确度  |  | 1 – 10 th  | 0.1%  | ±0.25 of reading ±1%  | 0.1mA / 0.1A  | ±0.2% of reading ±7dgts  |  | 11 – 20 th  | ±2% of reading ±1%  | ±2% of reading ±7dgts  |  | 2 1 – 50 th (A范围)  | ±5% of reading ±1%  | ±5% of reading ±7dgts  |  | 2 1 – 50 th (mA范围)  | ±10% of reading ±1%  | ±10% of reading ±7dgts  |  | 5 1 – 99 th  | ±35% of reading ±1%  | ±35% of reading ±7dgts  | 
 | 
| | AC(交流)电流的谐波分析(1~99阶)3007超大电流软性钩部  | 
  | 范围  | 百分比(%)  | 电流值(A)  |  | 分辨率  | 读值准确度  | 分辨率  | 读值准确度  |  | 1 – 20 th  | 0.1%  | ±2%  | 0.1A / 1A  | ±0.2% of Range ±0.4A/40A  |  | 21 – 50 th  | ± 6%  | ±4% of Range ± 0.4A/40A  |  | 51 – 99 th  | ±10%  | ±6% of Range ± 0.4A/40A  | 
 | 
|   | 范围  | 分辨率  | 读值准确度(6801)  | 读值准确度(6802)  | 读值准确度(3007)  |  | 0.0 – 20%  | 0.1%  | ±1%  | ±2%  | ±2%  |  | 20 – 100%  | 0.1%  | ±3% of reading ±5%  | ±6% of reading ±1%  | ±6% of reading ±1%  |  | 100 – 999.9%  | 0.1%  | ±10% of reading ±10%  | ±10% of reading ±1%  | ±10% of reading ±1%  | 
 | 
| | 交流电压峰值(峰值>5V) 或 AC电流(峰值>20A),VT=1  | 
  | 范围  | 取样时间  | 读值准确度  |  | 50Hz  | 19 μS  | ±5% ±30digits  |  | 60Hz  | 16 μS  | ±5% ±30 digits  | 
 | 
| | 谐波的波峰因素(C.F.)(峰值>5V) 或 ACA(峰值范围>10%),VT=1  | 
  | 范围  | 分辨率  | 读值准确度  |  | 1.00 – 99.99  | 0.01  | ±5% ±30digits  | 
 | 
|   | 范围  | 分辨率  | 读值准确度  |  | 45 – 65Hz  | 0.1Hz  | 0.2Hz  | 
 | 
|   | 范围  | 分辨率  | 读值准确度  |  | 0.00 – 1.00  | 0.01  | ± 0.04  | 
 | 
|   | 范围  | 分辨率  | 读值准确度  |  | -180 。 to 180 。  | 0.1 。  | ± 1 。  | 
 | 
|   | 钩部直径Φ(6801) | 约30mm  |  | 钩部直径Φ(6802) | 约55mm(approx.), 64 X 24mm(Bus Bar)  |  | 电池规格 | 1.5V SUM-3 x 8  |  | 显示 | 带有背光的大型点矩阵LCD  |  | 耗电量 | 约140mA  |  | 外部直流电源 | 直流12V的变压器 (为了操作**,一定要有600V耐压保护)  |  | 每周期取样速度 | 1024  |  | LCD显示更新速度 | 1 times / sec.  |  | 操作温度 | -10°C to 50°C |  | 储存温度 | -20°C to 60°C |  | 操作湿度 | < 85% relative  |  | 储存湿度 | < 75% relative  |  | 重量(6800) | 1160g (包括八个电池)  |  | 重量(6801) | 200g  |  | 重量(6802) | 600g  |  | 尺寸(6800) | 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)  |  | 尺寸(6801) | 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)  |  | 尺寸 (6802) | 244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H)  |  | 附件 | 四条测试棒与四个鳄鱼夹,携带用背袋x1,说明书x1,电池1.5V x 8  | 
 |